Multi-Function Aesthetic Device with 8 Handpieces - China Suppliers & Factory for Versatile Treatments
Introducing our advanced Multi-Function Aesthetic Device, designed to cater to a wide array of patient needs. This versatile platform, featuring 8 specialized handpieces, allows practitioners to perform over 80 different treatments, making it an essential choice for both new and experienced providers. As one of the leading suppliers in China, our factory ensures that each device meets the highest standards of quality and efficacy.
The innovative platform technology combines multiple procedures into one comprehensive solution. With 8 distinct handpieces tailored for various treatments, practitioners can easily select the optimal combination for their patients' unique requirements. Elevate your practice with the BL-M10 from BILENS—your trusted partner in aesthetic solutions.
The theory of selective photothermolysis has been pivotal in the advancement of laser surgery. It explains the mechanism Clinical, Cosmetic and Investigational Dermatology by which controlled destruction of a cutaneous target can be achieved without significant injury to surrounding tissue.
Three principles are crucial to the process. First, an appropriate wavelength should be employed that can be absorbed preferentially by the targeted tissue chromophore. Second, the pulse duration of the laser must be shorter than the chromophore’s thermal relaxation time, which is the time required for the target to lose half of its peak temperature following irradiation. Third, the fluence (or energy) must be sufficient to achieve destruction of the target within the appropriate time interval. These factors guide the selection of lasers and intense pulsed light (IPL) appropriate for a specific skin target or lesion.
IPL (Intense Pulsed Light)
Principle: Non-laser wide-spectrum pulsed light (400-1200nm), filter specific bands (such as 560/590nm), target melanin (pigment), hemoglobin (blood vessels) or water (hair removal).
Diode Laser
Principle: Semiconductor materials (such as GaAlAs) produce a single wavelength (commonly 808nm/810nm), target hair follicle melanin, and destroy hair papilla through photothermal effect.
Triple Diode Laser
Principle: Combine three semiconductor laser wavelengths (such as 755nm/808nm/1064nm) to act simultaneously on different depths and target tissues (melanin/hemoglobin).
Q-switched Nd:YAG Laser
Principle: Nd:YAG crystals generate 1064nm (or doubled 532nm) lasers, which are compressed to nanoseconds by Q-switching technology, and instantly blast pigment particles with high energy (photomechanical effect).
Er:YAG Fractional Laser
Principle: Er:YAG crystals emit 2940nm lasers, which are strongly absorbed by water, vaporize the epidermis or dermis to form micropores (fractional mode), and stimulate collagen regeneration.
1064nm Long Pulse Nd:YAG
Principle: Nd:YAG crystals generate 1064nm long pulses (milliseconds), targeting deep melanin or hemoglobin, and slowly heat the target through photothermal effect.
Er:Glass Fractional Laser
Principle: Erbium-doped glass fiber generates 1550nm laser, which is absorbed by the dermis water, forming a micro-thermal damage area (non-ablative fractional), promoting collagen remodeling.
Picosecond Nd:YAG Laser
Principle: Nd:YAG crystal generates ultra-short pulses (picosecond level, 10⁻¹² seconds), directly shattering pigment particles through photoacoustic effect (rather than photothermal), with higher efficiency than Q-switched laser.
MULTI-FUNCTION PLATFORM TECHNICAL SPECIFICATIONS
IPL SSR & SHR
Spot size
15*50mm or 12*35mm
Wavelength
420~1200nm
Filter
420/510/560/610/640/SHR (standard)
Energy density
1~50J/cm² (10-60 level)
Diode Laser
Laser output
1000W or 1600W
Wavelength
810nm / 755+808nm / 755+808nm+1064nm
Spot size
12*23mm or 14*50mm & 12*15mm
Energy density
1~62J/cm²
Repetition rate
1~10Hz
Pulse width
10~300ms
Sapphire cooling
-15~4°C
Picosecond Nd:YAG Laser
Wavelength
1064nm & 532nm
Spot size
1-5mm
Pulse width
<980ps
Max. Energy
800mJ (1064nm), 400mJ (532nm)
Repetition rate
1~10Hz
2940nm Er:YAG Fractional Ablative Laser
Spot size
7x7mm, 9x9mm, Zoom lens: 1~3.5mm, 6mm, 9mm
Pulse width
0.2~3ms
Energy
400~2600mJ
1540nm Er:Glass Fractional Laser
Spot size
10x10 mm
Energy
6~70mJ/microbeam
Pulse width
10ms, 15ms
1064nm Long Pulse Nd:YAG Laser
Spot size
2.2*5mm, 6mm, 9mm
Energy density
10~500J/cm²
Pulse width
10~40ms
Q-Switched Nd:YAG Laser
Wavelength
1064nm & 532nm
Spot size
1-5mm
Pulse width
<10ns (single pulse)
Repetition rate
1~10Hz
Max. Energy
2000mJ (1064nm), 1000mJ (532nm)
Operate interface
12.1' True color touch screen
Cooling
Advanced Air & TEC water cooling system
Power supply
AC 110V or 230V, 50/60Hz
Dimension
68*63*135cm (L*W*H)
Weight
69Kgs
MULTI-FUNCTION PLATFORM ADVANTAGES
A multi-function laser platform that integrates various laser technologies (such as IPL, Diode, Q-switch Nd:YAG, Er:YAG, Er:Glass, Picosecond, and Long Pulse 1064nm lasers) into a single system offers significant advantages for aesthetic and dermatological treatments. Here’s a breakdown of its key benefits:
Comparison of Laser Technologies in a Multi-Function Platform
Laser Type
Key Applications
Skin Types
IPL
Hair removal, pigmentation, vascular lesions
I-IV
Diode Laser
Hair removal (especially dark hair)
I-V
Q-Switch Nd:YAG (1064/532nm)
Tattoo removal, pigmentation
I-VI
Long Pulse 1064nm Nd:YAG
Deep vascular lesions, hair removal (darker skin)
IV-VI
Er:YAG Fractional
Skin resurfacing, scars, wrinkles
I-IV
Er:Glass Fractional (1540nm)
Skin tightening, acne scars
I-V
Picosecond Laser
Tattoos, pigmentation, collagen stimulation
I-VI
Conclusion
A multi-function laser platform is a smart investment for dermatology and aesthetic clinics, providing cost savings, versatility, and superior treatment outcomes. By integrating multiple laser technologies, it maximizes efficiency while offering customizable solutions for diverse patient needs.
Certifications honor
MULTI-FUNCTION PLATFORM APPLICATIONS
Technology Module
Clinical Applications
2940nm Er:YAG Fractional Laser
• Skin Resurfacing; Wart and Nevus removal; Skin Resurfacing; Wrinkles and Fine lines removal; Photodamge; Texture Irregularity
• Tighten vagina - Improve loose situation, makes the vaginal canal smaller.
• Clean the vagina - Female private parts maintenance.
• Moist vagina - Eliminate dryness
1540nm Er:Glass Fractional Laser
• Stretch Marks Removal; Skin resurfacing; Surgical scar, acne scar treatment; Stretch marks; Melasma removal; Deep wrinkle removal; Improve skin fine lines
1064nm Long Pulse Nd:YAG Laser
• Vascular Reduction; Permanent Hair Removal for all skin types; Leg Veins and Telangiectasia; Vascular lesion; Wrinkle Removal
What are the key benefits of choosing a multi-function laser platform over single-purpose machines?
A multi-function platform integrates several laser modalities (such as Diode, Nd:YAG, Er:YAG, and IPL) into a unified workstation. This significantly reduces equipment purchase and maintenance expenses, optimizes floor space, and allows clinical practitioners to offer comprehensive head-to-toe treatments using a single modular interface.
Can this platform treat all Fitzpatrick skin types (Types I through VI)?
Yes. The combination of varied wavelengths (from 532nm and 755nm to 808nm, 1064nm, and 2940nm) allows safe parameter customization across all Fitzpatrick skin types. For example, the Long Pulse 1064nm Nd:YAG laser provides proven safety for deeper skin tones (Types IV-VI), while shorter wavelengths precisely target lighter phototypes.
What is the difference between the Picosecond and Q-Switched Nd:YAG lasers in this platform?
While both target pigment and tattoo ink, the Picosecond laser generates ultra-short pulses (under 980ps) that pulverize pigment particles through a pure photoacoustic mechanism into fine dust. The Q-Switched Nd:YAG works in nanoseconds (<10ns) via photomechanical shockwaves. Picosecond treatments generally offer quicker clearance with less thermal risk.
How does the system protect the epidermis during high-energy procedures?
The system employs built-in advanced contact sapphire cooling (-15°C to 4°C) alongside a dual Air & TEC water cooling architecture. This delivers continuous epidermal protection before, during, and after pulses, maximizing patient comfort and minimizing downtime.
Can combination therapies be carried out during the same patient visit?
Yes. With interchangeable smart handpieces and quick modality switching, clinicians can seamlessly pair treatments—such as IPL for superficial vascular lesions followed by fractional Er:YAG or Er:Glass laser for collagen stimulation and scar resurfacing.
Is the system future-proof for future clinical expansion?
Yes, designed with a modular structure, the platform allows clinics to add new dedicated optical handpieces or adopt firmware enhancements without replacing the main chassis, protecting long-term capital investment.